Keckley
Solenoid Valves

Pilot Piston Operated, Semi-Direct Lift or Direct Lift Normally Closed or Normally Open Steam, Air, Gas, Water, Oil Service

The Type E direct operated Valve is simple in design, sturdy in construction, and dependable in service.

Line Pressure is the main actuating force. Coil lifts pilot valve only, allowing pressure in upper chamber to escape through piston, and line pressure opens valve. When pilot drops, pressure builds up over piston through timing orifice and line pressure holds valve closed.

Valve is tight closing and can be timed for different closing intervals. Avoids damaging vibration due to water hammer. Quick opening and closing prevents wire drawing when used on steam.

Piston Ring of special material insures long life. Cylinder and piston combination actually improves on continued use.

Coils are glass insulated, moisture proof, quiet and low current consumption. May be removed without breaking connection. Outlets may be placed in any direction.

The use of the Line Pressure as the main actuating force permits full flow in all sizes, on air, oil and water pressures from 1 to 300 psi. Maximum Steam pressure 200 psi.

The body material is bronze, the pilot valve material all stainless steel with one piece point and stem. Stainless steel springs.

Stainless Steel renewable main valves are furnished as standard for all sizes.

All sizes 1/4" to 3" have full flow. The flow is equivalent to the same size standard globe valve.

The Type E Solenoid Valve should be selected when operating pressures are below the 20 psi minimum required for the Type EA shown on page 21.

Also available are valves with manual adjustment of valve closing speed on liquids.

Operating sequence:

TO OPEN: When current is applied, the plunger lifts pilot Valve from seat relieving the pressure on top of piston, allowing pressure release through pilot Valve orifice. Since pilot orifice is larger than timing orifice pressure on the lower side of piston is greater and line pressure subsequently opens inner valve.

TO CLOSE: When current is off, pilot Valve drops into pilot orifice preventing escape of media through piston. This causes pressure to build up above the piston through timing orifice. The spring returns the piston to the closed position and line pressure on top of piston holds Valve closed.

Applications:

WATER: Feed water make up, float level control, cooling of air compressors, automatic batching equipment.

AIR & GAS SIGNALS: Unloading air compressors.

STEAM: Temperature control in heating and processing.

OIL: Hydraulic elevators (manual control) closing adjustment.

Data required when ordering for both Type E and EA: Pipe Size - Media used - Maximum and Minimum pressures. Maximum temp. Kind of current, cycles if A.C. Approximate back pressure. Continuous or intermittent service. Longest time coil to be energized. Standard Voltages - 110-220 Volt, 60-50-25 cycle A.C. 440 Volt, 60-50 cycle A.C. -115-230 Volt. D.C. Normally open or normally closed.